ChipFind - документация

Электронный компонент: 74AC125MTR

Скачать:  PDF   ZIP
1/9
July 2001
s
HIGH SPEED: t
PD
= 4ns (TYP.) at V
CC
= 5V
s
LOW POWER DISSIPATION:
I
CC
= 4
A(MAX.) at T
A
=25C
s
HIGH NOISE IMMUNITY:
V
NIH
= V
NIL
= 28 % V
CC
(MIN.)
s
50
TRANSMISSION LINE DRIVING
CAPABILITY
s
SYMMETRICAL OUTPUT IMPEDANCE:
|I
OH
| = I
OL
= 24mA (MIN)
s
BALANCED PROPAGATION DELAYS:
t
PLH
t
PHL
s
OPERATING VOLTAGE RANGE:
V
CC
(OPR) = 2V to 6V
s
PIN AND FUNCTION COMPATIBLE WITH
74 SERIES 125
s
IMPROVED LATCH-UP IMMUNITY
DESCRIPTION
The 74AC125 is an advanced high-speed CMOS
QUAD BUS BUFFER fabricated with sub-micron
silicon gate and double-layer metal wiring C
2
MOS
technology.
The device requires the 3-STATE control input G
to be set high to place the output go in to the high
impedance state.
All inputs and outputs are equipped with
protection circuits against static discharge, giving
them 2KV ESD immunity and transient excess
voltage.
74AC125
QUAD BUS BUFFERS (3-STATE)
PIN CONNECTION AND IEC LOGIC SYMBOLS
ORDER CODES
PACKAGE
TUBE
T & R
DIP
74AC125B
SOP
74AC125M
74AC125MTR
TSSOP
74AC125TTR
TSSOP
DIP
SOP
74AC125
2/9
INPUT AND OUTPUT EQUIVALENT CIRCUIT
PIN DESCRIPTION
TRUTH TABLE
X : Don't Care
Z : High Impedance
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these conditions is
not implied.
RECOMMENDED OPERATING CONDITIONS
1) V
IN
from 30% to 70% of V
CC
PIN No
SYMBOL
NAME AND FUNCTION
1, 4, 10, 13
1G to 4G
Output Enable Inputs
2, 5, 9, 12
1A to 4A
Data Inputs
3, 6, 8, 11
1Y to 4Y
Data Outputs
7
GND
Ground (0V)
14
V
CC
Positive Supply Voltage
A
G
Y
X
H
Z
L
L
L
H
L
H
Symbol
Parameter
Value
Unit
V
CC
Supply Voltage
-0.5 to +7
V
V
I
DC Input Voltage
-0.5 to V
CC
+ 0.5
V
V
O
DC Output Voltage
-0.5 to V
CC
+ 0.5
V
I
IK
DC Input Diode Current
20
mA
I
OK
DC Output Diode Current
20
mA
I
O
DC Output Current
50
mA
I
CC
or I
GND
DC V
CC
or Ground Current
200
mA
T
stg
Storage Temperature
-65 to +150
C
T
L
Lead Temperature (10 sec)
300
C
Symbol
Parameter
Value
Unit
V
CC
Supply Voltage
2 to 6
V
V
I
Input Voltage
0 to V
CC
V
V
O
Output Voltage
0 to V
CC
V
T
op
Operating Temperature
-55 to 125
C
dt/dv
Input Rise and Fall Time V
CC
= 3.0, 4.5 or 5.5V (note 1)
8
ns/V
74AC125
3/9
DC SPECIFICATIONS
1) Maximum test duration 2ms, one output loaded at time
2) Incident wave switching is guaranteed on transmission lines with impedances as low as 50
AC ELECTRICAL CHARACTERISTICS
(*) Voltage range is 3.3V
0.3V
(**) Voltage range is 5.0V
0.5V
Symbol
Parameter
Test Condition
Value
Unit
V
CC
(V)
T
A
= 25C
-40 to 85C
-55 to 125C
Min.
Typ.
Max.
Min.
Max.
Min.
Max.
V
IH
High Level Input
Voltage
3.0
V
O
= 0.1 V or
V
CC
-0.1V
2.1
1.5
2.1
2.1
V
4.5
3.15
2.25
3.15
3.15
5.5
3.85
2.75
3.85
3.85
V
IL
Low Level Input
Voltage
3.0
V
O
= 0.1 V or
V
CC
-0.1V
1.5
0.9
0.9
0.9
V
4.5
2.25
1.35
1.35
1.35
5.5
2.75
1.65
1.65
1.65
V
OH
High Level Output
Voltage
3.0
I
O
=-50
A
2.9
2.99
2.9
2.9
V
4.5
I
O
=-50
A
4.4
4.49
4.4
4.4
5.5
I
O
=-50
A
5.4
5.49
5.4
5.4
3.0
I
O
=-12 mA
2.56
2.46
2.4
4.5
I
O
=-24 mA
3.86
3.76
3.7
5.5
I
O
=-24 mA
4.86
4.76
4.7
V
OL
Low Level Output
Voltage
3.0
I
O
=50
A
0.002
0.1
0.1
0.1
V
4.5
I
O
=50
A
0.001
0.1
0.1
0.1
5.5
I
O
=50
A
0.001
0.1
0.1
0.1
3.0
I
O
=12 mA
0.36
0.44
0.5
4.5
I
O
=24 mA
0.36
0.44
0.5
5.5
I
O
=24 mA
0.36
0.44
0.5
I
I
Input Leakage
Current
5.5
V
I
= V
CC
or GND
0.1
1
1
A
I
OZ
High Impedance
Output Leakage
Current
5.5
V
I
= V
IH
or V
IL
V
O
= V
CC
or GND
0.5
5
10
A
I
CC
Quiescent Supply
Current
5.5
V
I
= V
CC
or GND
4
40
80
A
I
OLD
Dynamic Output
Current (note 1, 2)
5.5
V
OLD
= 1.65 V max
75
50
mA
I
OHD
V
OHD
= 3.85 V min
-75
-50
mA
Symbol
Parameter
Test Condition
Value
Unit
V
CC
(V)
T
A
= 25C
-40 to 85C
-55 to 125C
Min.
Typ.
Max.
Min.
Max.
Min.
Max.
t
PLH
t
PHL
Propagation Delay
Time
3.3
(*)
1.0
5.5
8.5
1.0
9.5
1.0
10.5
ns
5.0
(**)
1.0
4.0
7.0
1.0
8.5
1.0
8.5
t
PZL
t
PZH
Output Enable
Time
3.3
(*)
1.0
6.0
10.0
1.0
11.0
1.0
11.0
ns
5.0
(**)
1.0
4.0
7.0
1.0
8.0
1.0
8.0
t
PLZ
t
PHZ
Output Disable
Time
3.3
(*)
1.0
7.5
10.0
1.0
11.0
1.0
11.0
ns
5.0
(**)
1.0
6.0
9.0
1.0
9.5
1.0
9.5
74AC125
4/9
CAPACITIVE CHARACTERISTICS
1) C
PD
is defined as the value of the IC's internal equivalent capacitance which is calculated from the operating current consumption without
load. (Refer to Test Circuit). Average operating current can be obtained by the following equation. I
CC(opr)
= C
PD
x V
CC
x f
IN
+ I
CC
/4 (per
Buffer)
TEST CIRCUIT
C
L
= 50pF or equivalent (includes jig and probe capacitance)
R
L
= R
1
= 500
or equivalent
R
T
= Z
OUT
of pulse generator (typically 50
)
Symbol
Parameter
Test Condition
Value
Unit
V
CC
(V)
T
A
= 25C
-40 to 85C
-55 to 125C
Min.
Typ.
Max.
Min.
Max.
Min.
Max.
C
IN
Input Capacitance
5.0
4
pF
C
OUT
Output
Capacitance
5.0
8
pF
C
PD
Power Dissipation
Capacitance (note
1)
5.0
f
IN
= 10MHz
24
pF
TEST
SWITCH
t
PLH
, t
PHL
Open
t
PZL
, t
PLZ
2V
CC
t
PZH
, t
PHZ
Open
74AC125
5/9
WAVEFORM 1: PROPAGATION DELAYS (f=1MHz; 50% duty cycle)
WAVEFORM 2: OUTPUT ENABLE AND DISABLE TIME (f=1MHz; 50% duty cycle)