ChipFind - документация

Электронный компонент: 74V1G126CTR

Скачать:  PDF   ZIP
1/10
July 2001
s
HIGH SPEED: t
PD
= 3.4ns (TYP.) at V
CC
= 5V
s
LOW POWER DISSIPATION:
I
CC
= 1
A(MAX.) at T
A
=25C
s
HIGH NOISE IMMUNITY:
V
NIH
= V
NIL
= 28% V
CC
(MIN.)
s
POWER DOWN PROTECTION ON INPUTS
s
SYMMETRICAL OUTPUT IMPEDANCE:
|I
OH
| = I
OL
= 8mA (MIN) at V
CC
= 4.5V
s
BALANCED PROPAGATION DELAYS:
t
PLH
t
PHL
s
OPERATING VOLTAGE RANGE:
V
CC
(OPR) = 2V to 5.5V
s
IMPROVED LATCH-UP IMMUNITY
DESCRIPTION
The 74V1G126 is an advanced high-speed CMOS
SINGLE BUS BUFFER fabricated with sub-micron
silicon gate and double-layer metal wiring C
2
MOS
technology.
3-STATE control input 1G has to be set LOW to
place the output into the high impedance state.
Power down protection is provided on all inputs
and 0 to 7V can be accepted on inputs with no
regard to the supply voltage. This device can be
used to interface 5V to 3V.
74V1G126
SINGLE BUS BUFFER (3-STATE)
PIN CONNECTION AND IEC LOGIC SYMBOLS
ORDER CODES
PACKAGE
T & R
SOT23-5L
74V1G126STR
SOT323-5L
74V1G126CTR
SOT323-5L
SOT23-5L
74V1G126
2/10
INPUT EQUIVALENT CIRCUIT
PIN DESCRIPTION
TRUTH TABLE
X : Don't Care
Z : High Impedance
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these conditions is
not implied.
RECOMMENDED OPERATING CONDITIONS
1) V
IN
from 30% to 70% of V
CC
PIN No
SYMBOL
NAME AND FUNCTION
1
1G
Output Enable Input
2
1A
Data Input
4
1Y
Data Output
3
GND
Ground (0V)
5
V
CC
Positive Supply Voltage
A
G
Y
X
L
Z
L
H
L
H
H
H
Symbol
Parameter
Value
Unit
V
CC
Supply Voltage
-0.5 to +7.0
V
V
I
DC Input Voltage
-0.5 to +7.0
V
V
O
DC Output Voltage
-0.5 to V
CC
+ 0.5
V
I
IK
DC Input Diode Current
- 20
mA
I
OK
DC Output Diode Current
20
mA
I
O
DC Output Current
25
mA
I
CC
or I
GND
DC V
CC
or Ground Current
50
mA
T
stg
Storage Temperature
-65 to +150
C
T
L
Lead Temperature (10 sec)
260
C
Symbol
Parameter
Value
Unit
V
CC
Supply Voltage
2 to 5.5
V
V
I
Input Voltage
0 to 5.5
V
V
O
Output Voltage
0 to V
CC
V
T
op
Operating Temperature
-55 to 125
C
dt/dv
Input Rise and Fall Time (note 1) (V
CC
= 3.3
0.3V)
(V
CC
= 5.0
0.5V)
0 to 100
0 to 20
ns/V
ns/V
74V1G126
3/10
DC SPECIFICATIONS
AC ELECTRICAL CHARACTERISTICS (Input t
r
= t
f
= 3ns)
(*) Voltage range is 3.3V
0.3V
(**) Voltage range is 5.0V
0.5V
Symbol
Parameter
Test Condition
Value
Unit
V
CC
(V)
T
A
= 25C
-40 to 85C
-55 to 125C
Min.
Typ.
Max.
Min.
Max.
Min.
Max.
V
IH
High Level Input
Voltage
2.0
1.5
1.5
1.5
V
3.0 to
5.5
0.7V
CC
0.7V
CC
0.7V
CC
V
IL
Low Level Input
Voltage
2.0
0.5
0.5
0.5
V
3.0 to
5.5
0.3V
CC
0.3V
CC
0.3V
CC
V
OH
High Level Output
Voltage
2.0
I
O
=-50
A
1.9
2.0
1.9
1.9
V
3.0
I
O
=-50
A
2.9
3.0
2.9
2.9
4.5
I
O
=-50
A
4.4
4.5
4.4
4.4
3.0
I
O
=-4 mA
2.58
2.48
2.4
4.5
I
O
=-8 mA
3.94
3.8
3.7
V
OL
Low Level Output
Voltage
2.0
I
O
=50
A
0.0
0.1
0.1
0.1
V
3.0
I
O
=50
A
0.0
0.1
0.1
0.1
4.5
I
O
=50
A
0.0
0.1
0.1
0.1
3.0
I
O
=4 mA
0.36
0.44
0.55
4.5
I
O
=8 mA
0.36
0.44
0.55
I
OZ
High Impedance
Output Leakage
Current
5.5
V
I
= V
IH
or V
IL
V
O
= V
CC
or GND
0.25
2.5
5
A
I
I
Input Leakage
Current
0 to
5.5
V
I
= 5.5V or GND
0.1
1
1
A
I
CC
Quiescent Supply
Current
5.5
V
I
= V
CC
or GND
1
10
20
A
Symbol
Parameter
Test Condition
Value
Unit
V
CC
(V)
C
L
(pF)
T
A
= 25C
-40 to 85C
-55 to 125C
Min.
Typ.
Max.
Min.
Max.
Min.
Max.
t
PLH
t
PHL
Propagation Delay
Time
3.3
(*)
15
4.7
7.5
1.0
8.5
1.0
9.5
ns
3.3
(*)
50
5.2
8.0
1.0
9.5
1.0
10.5
5.0
(**)
15
3.4
5.5
1.0
6.5
1.0
7.5
5.0
(**)
50
3.7
6.5
1.0
7.5
1.0
8.5
t
PLZ
t
PHZ
Output Disable
Time
3.3
(*)
15
4.4
8.0
1.0
9.0
1.0
10.0
ns
3.3
(*)
50
4.8
11.5
1.0
12.5
1.0
13.5
5.0
(**)
15
3.0
5.0
1.0
6.0
1.0
7.0
5.0
(**)
50
3.2
7.0
1.0
8.0
1.0
9.0
t
PZL
t
PZH
Output Enable
Time
3.3
(*)
15
4.8
7.6
1.0
9.5
1.0
10.5
ns
3.3
(*)
50
5.3
8.5
1.0
10.0
1.0
11.0
5.0
(**)
15
3.6
5.9
1.0
7.0
1.0
8.0
5.0
(**)
50
3.9
6.5
1.0
7.5
1.0
8.5
74V1G126
4/10
CAPACITIVE CHARACTERISTICS
1) C
PD
is defined as the value of the IC's internal equivalent capacitance which is calculated from the operating current consumption without
load. (Refer to Test Circuit). Average operating current can be obtained by the following equation. I
CC(opr)
= C
PD
x V
CC
x f
IN
+ I
CC
TEST CIRCUIT
C
L
=15/50pF or equivalent (includes jig and probe capacitance)
R1 = 1K
or equivalent
R
T
= Z
OUT
of pulse generator (typically 50
)
Symbol
Parameter
Test Condition
Value
Unit
T
A
= 25C
-40 to 85C
-55 to 125C
Min.
Typ.
Max.
Min.
Max.
Min.
Max.
C
IN
Input Capacitance
4
10
10
10
pF
C
OUT
Output
Capacitance
10
pF
C
PD
Power Dissipation
Capacitance
(note 1)
10
pF
TEST
SWITCH
t
PLH
, t
PHL
Open
t
PZL
, t
PLZ
V
CC
t
PZH
, t
PHZ
GND
74V1G126
5/10
WAVEFORM 1 : PROPAGATION DELAYS (f=1MHz; 50% duty cycle)