ChipFind - документация

Электронный компонент: PPS-125-24

Скачать:  PDF   ZIP
SPECIFICATION
PPS-125-3.3
PPS-125-5
PPS-125-12
PPS-125-13.5 PPS-125-15
PPS-125-24
PPS-125-27
PPS-125-48
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER (convection)
RATED POWER (18CFM FAN)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
PACKING
OVER LOAD
OVER VOLTAGE
AC CURRENT
3.3V
5V
12V
13.5V
15V
24V
27V
48V
20A
20A
8.5A
7.5A
6.7A
4.2A
3.8A
2.1A
0 ~ 20A
0 ~ 25A
0 ~ 20A
0 ~ 25A
0 ~ 8.5A
0 ~ 10.5A
0 ~ 7.5A
0 ~ 9.3A
0 ~ 6.7A
0 ~ 8.4A
0 ~ 4.2A
0 ~ 5.2A
0 ~ 3.8A
0 ~ 4.6A
0 ~ 2.1A
0 ~ 2.6A
66W
82.5W
100W
125W
102W
126W
101.25W
125.55W
100.5W
126W
100.8W
124.8W
102.6W
124.2W
100.8W
124.8W
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
150mVp-p
150mVp-p
250mVp-p
3.13 ~ 3.46V
4.75 ~ 5.25V
11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V
2.0%
2.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1000ms, 30ms, 20ms/230VAC
2000ms, 30ms, 20ms/115VAC at full load
90 ~ 264VAC
127 ~ 370VDC
47~63Hz
PF>0.93/230VAC
PF>0.98/115VAC at full load
70%
79%
80%
80%
80%
83%
83%
83%
1.2A
115VAC
230VAC
0.6A
COLD START 40A/230VAC
<2mA / 240VAC
130 ~ 160% rated output power
3.63 ~ 4.45V
5.5 ~ 6.75V
13.8 ~ 16.2V
15.5 ~ 20.25V
17.25 ~ 20.25V 27.6 ~ 32.4V
31.05 ~ 36.45V 57.6 ~ 67.2V
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
UL60950-1, TUV EN60950-1 Approved
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
-20 ~ +70
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.05%/
(0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
111.7Khrs min.
MIL-HDBK-217F (25
)
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/13.3Kg/0.89CUFT
1.7A
0.75A
125W Single Output with PFC Function
P P S - 1 2 5
s e r i e s
3
Universal AC input / Full range
Built-in active PFC function
Protections:Short circuit/Over load/Over voltage
PWM control and regulated
High power density 6.117W/inch
Built-in remote sense function
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
Features :
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY &
EMC
(Note 4)
PROTECTION
ENVIRONMENT
EMI CONDUCTION & RADIATION
CURRENT RANGE (convection)
CURRENT RANGE (18CFM FAN)
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
TOTAL POWER INT'L
Mechanical Specification
Derating Curve
Output Derating VS Input Voltage
AC Input Connector (CN1) : JST B3P-VH or equivalent
DC Output Connector (CN4) : JST B8P-VH or equivalent
Pin No.
Pin No.
1
1~4
3
5~8
2
Assignment
Assignment
AC/L
-V
AC/N
+V
No Pin
Mating Housing
Mating Housing
JST VHR
JST VHR
or equivalent
or equivalent
Terminal
Terminal
JST SVH-21T-P1.1
JST SVH-21T-P1.1
or equivalent
or equivalent
Unit:mm
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (V) 60Hz
85
100
115
135
155
264
100
90
80
70
60
50
40
L
O
A
D(
%
)
L
O
A
D
(
%
)
-20
0
10
20 25 30
40
50
60
70
20
50
70
100
125
Free air Convection
(CN3) : Remote Sense
Pin No.
1
2
Assignment
RS-
RS+
Forced air 18CFM
1
2
CN3
1
CN4
8
7
6
4
3
2
5
F
S
1
T
2
A
2
5
0
V
A
C
1
CN1
3
SVR1
LED1
4 -
3 .5
115.6
127
6
4
.
8
7
6
.
2
3
4
.
6
2
Air flow
direction
125W Single Output with PFC Function
P P S - 1 2 5
s e r i e s