Protection type : Hiccup mode, recovers automatically after fault condition is removed
SPECIFICATION
MODEL
T-40A
T-40B
T-40C
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
3A
2A
0.5A
3A
2A
0.5A
3A
1.5A
0.5A
0.6 ~ 5A
0.2 ~ 3A
0.1 ~ 1A
0.6 ~ 5A
0.2 ~ 3A
0.1 ~ 1A
0.6 ~ 5A
0.2 ~ 2A
0.1 ~ 1A
41.5W
45W
45W
100mVp-p
120mVp-p
100mVp-p
100mVp-p
120mVp-p
120mVp-p
100mVp-p
120mVp-p
120mVp-p
CH1 : 4.75 ~ 5.5V
CH1 : 4.75 ~ 5.5V
CH1 : 4.75 ~ 5.5V
2.0%
6.0%
8.0%
2.0%
6.0%
8.0%
2.0%
6.0%
6.0%
0.5%
0.5%
1.0%
1.0%
0.5%
0.5%
1.0%
1.0%
0.5%
0.5%
1.0%
1.0%
4.0%
6.0%
4.0%
6.0%
4.0%
4.0%
800ms, 50ms, 60ms/230VAC
1.6s, 50ms,16ms/115VAC at full load
85 ~ 264VAC
120 ~ 370VDC
47 ~ 63Hz
72%/115VAC
72%/115VAC
72%/115VAC
5V: 5.75 ~ 6.75V
1.2A/115VAC
0.7A/230VAC
COLD START 20A/115VAC
40A/230VAC
<3.5mA / 240VAC
105 ~ 150%/115VAC of rate load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CSA 950, (UL1950, IEC950, TUV EN60950) Approved
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
-10 ~ +60
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/
(0 ~ 50
)on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
305.6K hrs min.
MIL-HDBK-217F (25
)
129*98*38mm (L*W*H)
0.45Kg; 30pcs/13.5Kg/0.86CUFT
40W Triple Output Switching Power Supply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 40KHz
2 years warranty
Features :
T- 4 0
s e r i e s
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
EMI CONDUCTION & RADIATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
TOTAL POWER INT'L