ChipFind - документация

Электронный компонент: MIM-93M2AKL

Скачать:  PDF   ZIP
INFRARED RECEIVER MODULE
MIM-93M2AKL
Description
Features
l
Photo detector and preamplifier in one package
l
Internal filter for PCM frequency
l
High immunity against ambient light
l
Improved shielding against electric field disturbance
l
5-Volt supply voltage; low power consumption
l
TTL and CMOS compatibility
BLOCK DIAGRAM
07/06/2000
Unity Opto Technology Co., Ltd.
The MIM-93M2AKL is 37.9 KH
Z
miniaturized infrared
receivers for remote control and other appplications
requiring improved ambient light rejection.
The separate PIN diode and preamplifier IC are assembled
on a single leadframe.
The epoxy package contains a special IR filter.
This module has excellent performance even in disturbed
ambient light applications and provides protection against
uncontrolled output pulses.
Output
V
S
GND
ABLC
TRAP
BPF
TRIMMING
f
o
MIM-93M2AKL
Absolute Maximum Ratings
Item
Symbol
Ratings
Unit
Remark
Supply voltage
V
CC
5.8
V
Operating temperature
T
opr
-10 ~ + 60
C
Storage temperature
T
stg
-20 ~ + 75
C
Soldering temperature
T
sd
260
C
Maximum 5 seconds
Electro-optical characteristics (Vcc=5V)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Remarks
Current consumption
Icc
5.0
mA
Under no signal
Response wavelength
p
940
nm
Tuning frequency
f
0
37.9
KH
Z
Output form
- - - - - active low output - - - - -
H level output voltage
V
0
h
4.2
V
L level output voltage
V
0
l
0.5
V
H level output pulse width
Twh
400
800
s
L level output pulse width
Twl
400
800
s
Distance between emitter & detector
L
10.0
m
Note 1
Half angle
45
deg
Horizonal direction
Test Method
A. Standard Transmitter
B. Detection Length Test
07/06/2000
Unity Opto Technology Co., Ltd.
@ Ta=25C
carrier frequency f
0
duty 50%
ON/OFF pulse width satisfied from 25 cm to detection limit
600
s
600
s
600
s
Fig 1. Burst Wave
Fig 2. Standard Transmitter Measurement circuit
+5V
10
F
PD3516
10k
V
out
25cm
Transmitter
Duty 50%
Oscilloscope
GND
10k
(T
a
=25C , Vcc=5V)
V
out
D.U.T
L
Transmitter output
: indicates horizontal and vertical directions
MIM-93M2AKL
C . Pulse Width Test
Application Circuit
CHARACTERISTIC CURVES (T
A
=25C)
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place .........Indoor without extreme reflection of light.
(2)Ambient light source... Detecting surface illumination shall be 20050Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter ... Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
07/06/2000
Unity Opto Technology Co., Ltd.
SUPPLY VOLTAGE vs. SUPPLY CURRENT
Supply Current Icc (mA)
2.2
2.8
2.7
2.6
2.4
2.0
2
3
4
5
6
7
8
Supply Voltage Vcc (V)
INPUT LEVEL vs.OUTPUT PULSE WIDTH
Input Level V
IN
(mV
P-P
)
400
500
600
700
800
900
0.1
1
10
100
100
0
Burst length * 600
s, cycle = 1.2ms
tpw: Average value of output from start
of signal input to 60th pulse
Output Pulse Width t
PW
(
s)
Input Level (mV
p-p
)
600
s
Transmitter output
DUT output pulse
600
s
V
0
l
V
0
h
Twl
Twh
MIE-544A2
MIM-93M2AKL
3
1
2
102P
Decoder
GND
Vcc **)
*) only necessary to supress power supply disturbances.
**) tolerated supply voltage range : 4.1V < Vcc < 5.8V
C
MIM-93M2AKL
Reliability
Test item
Test condition
Standard
High temparature
Ta=+60C Vcc=5.0 V t=240H
Note 2.
High temp. & high humi.
Ta=+40C 90%RH Vcc=5.0V t=240H
Note 2.
Low temparature
Ta= -10C Vcc=5.0V t=240H
Note 2.
Heat cycle
-20C(0.5H) ~ +75C(0.5H) 20cycle
Note 2.
Dropping
Test devices shall be dropped 3 times naturally
Note 3.
onto hard wooden board from a 75cm height position.
NOTE 2. (electro-optical charactistics) shall be satisfied sfter leaving 2 hours in the
normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
and destructions of appearance .(excepting deforms of terminals)
Inspection standard
1.Among electrical characteristics , total number shall be inspected on items blow.
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
CAUTION ( When use and storage of this device )
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
, the soldering iron is connected to ground before using .
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
07/06/2000
Unity Opto Technology Co., Ltd.
MIM-93M2AKL
Guarantee period and scope
1.Guarantee period
One year after delivery to desired place .
2.Guarantee scope
A re-delivery of goods will be carried out if the cause of malfunction lies in our
device .However no responsibilities be taken for the inconveniences caused by
the malfunction of our devices .
Others
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
covering the said problem .
07/06/2000
Unity Opto Technology Co., Ltd.