ChipFind - документация

Электронный компонент: FM4808C21

Скачать:  PDF   ZIP
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FM48, Filter Module
Rev. 2.3
Page 1 of 4
Set your site on VICOR at www.vicorpower.com
4
5
Shown actual size:
2.28 x 1.45 x 0.5 in
57,9 x 36,8 x 12,7 mm
Data Sheet
FM48
TM
FiltMod
Input Filter Module
Features
EMI filtering
8 and 12 Amp versions
CE Marked
Micro-size package
Low profile mounting option
Products Highlights
The FM48 input filter module enables
designers to meet the conducted
emission limits of EN55022 Level B
and FCC Level B when used with
Vicor's 48 Volt 2nd Generation of
DC-DC converters. FiltMods accept
an input voltage of 36 to 76Vdc with
a transient withstand capability of
100 Vdc for 100 msec. The FiltMods are
packaged in an industry standard
"quarter-brick" module measuring
2.28" x 1.45" x 0.5" and are available
in either 8 or 12 Ampere capacity.
Both versions may be on-board or
in-board mounted for height critical
applications. The FiltMods can be used
with Vicor's IAM48 for transient and
surge protection.
Compatible Products
IAM48
2nd Generation 48 V input
DC-DC converters
Note: For alternative product grades, change the "C" in the part number to "T".
Parameter
Min
Typ
Max
Remarks
Input voltage
36 Vdc
48 Vdc
76 Vdc
Safety approvals
UL 1950, CSA 22.2-950, EN 60950
Dielectric withstand
1,500 Vrms
Input /Output to base
EMI/ RFI
Telcordia GR-001089-Core Issue 2
When used with Vicor 2nd
EN 55022 Level B
Generation 48Vin DC-DC converters
FCC Part 15 Level B
Output current
FM4808C12
8 A
Delivered current to any
FM4812C12
12 A
combination of Vicor's 2nd Generation
48Vin DC-DC converter
Reverse polarity protection
No damage to unit, external
fusing required
Weight
2.1 ounces (60 grams)
Parameter
C-Grade
T-Grade
Storage temp.
40C to +125C
40C to +125C
Operating temp. (baseplate)
20C to +100C
40C to +100C
Warranty
2 years
2 years
Product Grade Specifications
FM48-FiltMod Specifications
(At T
BP
= 25C, nominal line, 75% load, unless otherwise specified)
Parameter
Rating Unit
Notes
+In to In
80
Vdc
Continuous
+In to In
100
V
100 ms
+Out to Out
75
Vdc
Continuous
Mounting torque
5 (0.57)
in-lbs (N-M)
<5 sec, wave solder
Pin soldering temperature
500 (260)
F(C)
<7 sec, hand solder
Pin soldering temperature
750 (390)
F(C)
Storage temperature C,T Grade
-40 to +125
C
Operating temperature C Grade
-20 to +100
C
Baseplate
Operating temperature T Grade
-40 to +100
C
Baseplate
Absolute Maximum Rating
FM
48
08
C
1
1
Output Current
08= 8 Amp
12=12 Amp
Pin Style
1= Short Pin
2= Long Pin
S= Short ModuMate
N= Long ModuMate
Baseplate
1=Slotted
2=Threaded
3=Thru-hole
Product Grade
C=-20 to 100C
T=-40 to 100C
Input
Voltage
Product
Part Numbers
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FM48, Filter Module
Rev. 2.3
Page 2 of 4
Set your site on VICOR at www.vicorpower.com
Typical Transient, Surge Protection and Filtering Solution
IAM2
2nd Generation
48Vdc Input
DC-DC Converters
IN
PR
PC
+IN
OUT
S
SC
+S
+OUT
FM48
IN
+IN
IAM48
4 3 2 1
7 6 5
4 3 2 1
7 6 5
Note: The IAM48 is shown in the on state.
To disable, open the connection to pin 3.
IN
NC
NC
+IN
OUT
GND
+ OUT
OUT
NC
Off/On
+OUT
IN
NC
+ IN
Conducted Noise
Figure 1--
FM4812C12 and Model V48A12C500A
DC-DC converter.
Figure 2--
FM4812C12 and Model V48B24C250A
DC-DC converter.
Figure 3
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FM48, Filter Module
Rev. 2.3
Page 3 of 4
Set your site on VICOR at www.vicorpower.com
Mechanical Drawings (FM48-FiltMod)
5
6
7
4
3
2
1
(REF)
0.080
2,03
DIA. (7X)
0.21
5,2
0.27
6,9
(2X)
1.04
26,4
1.45
36,8
0.275
6,99
0.800
20,32
0.525
13,34
0.400
10,16
0.12*
3,1
0.20**
5,08
FULL R (6X)
0.10
2,5
CHAMFER
(REF.)
(6X)
0.65
16,5
0.49
12,4
1.30
33,0
2.28
57,9
1.45
36,8
0.13
3,3
0.06
1,5
R
(3X)
0.01
X 45
Use a
4-40 Screw (6x)
Torque to:
5 in-lbs
0.57 N-m
0.54
13,7
0.43
10,9
Pin Style 2&N
(Long Pin)
0.62
15,7
Pin Style 1&S
(Short Pin)
(7X)
(7X)
Slotted (Style 1)
or
Threaded (Style 2)
4-40 UNC-2B (6X)
or
Thru Hole (Style 3)
#30 Drill Thru (6X)
(0.1285)
(ALL MARKINGS
THIS SURF
A
CE)
ALUMINUM
BASEPLATE
12,7
0,5
0.50
0.02
* Style 1 baseplate only
** Style 2 & 3 baseplates
*** Reserved for Vicor accessories
Not for mounting
style 2 & 3
baseplates only
(4X)***
0.490
.015
12,45
0,38
(REF)
2.000
50,80
0.235
.015
5,97
0,38
(REF)
0.350
.015
8,89
0,38
(REF)
1.27
32,3
0.09
2,3
Module Outline
2
3
6
1
7
4
5
PLATED
THRU HOLE
DIA
0,08
*DENOTES TOL =
0.003
0.133
3,38
1.734**
44,04
.400*
10,16
1.140**
28,96
0.170*
4,32
0.800*
20,32
0.525*
13,34
0.275*
6,99
2.000*
50,80
0.06
1,5
R
(4X)
INBOARD
SOLDER
MOUNT
PIN STYLE 1&S
0.094
0.003
2,39
0,08
0.43
10,9
(7X)
**PCB WINDOW
PCB THICKNESS
0.062
0.010
1,57
0,25
0.53
13,5
ONBOARD
SOLDER
MOUNT
PIN STYLE 2&N
0.094
0.003
2,39
0,08
PIN OUTS
No.
Function
Label
1
+Vin
+V
2
N/C
3
N/C
4
Vin
V
5
Vout
V
6
Ground
GND
7
+Vout
+V
Unless otherwise specified,
dimensions are in inches
mm
Decimals
Tol.
Angles
0.XX
0.01
0.25
1
0.XXX
0.005
0.127
PCB Mounting Specifications
PINS STYLES
STYLE 1 & 2: TIN/LEAD
HOT SOLDER DIPPED
STYLE S & N: GOLD PLATED COPPER
ALUMINUM
BASEPLATE
ALL MARKINGS
THIS SURFACE
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
FM48, Filter Module
P/N23295
Rev. 2.3 05/04/10M
Set your site on VICOR at www.vicorpower.com
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
Email
Vicor Express: vicorexp@vicr.com
Technical Support: apps@vicr.com
Component Solutions
for Your Power System
4
5
Vicor's comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is
assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life
support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to
Vicor's Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.