Parameter
Rating
Unit
Notes
L to N voltage
264
Vrms
Continuous
+Out to Out voltage
400
Vdc
B OK to Out voltage
16
Vdc
EN to Out voltage
16
Vdc
Mounting torque
15 (1.7)
in-lbs (N-m)
6 M4 x 0.7
Operating temperature
95
C
Chassis/BP
Storage temperature
125
C
Ambient
4
5
Absolute Maximum Ratings
Part Numbering
IFE
International AC Front End
500 Watts
Features
Autoranging 115/230 Vac input
Two, low profile,
chassis mount versions
500 Watts
Meets EN55022-B
Meets EN61000-3-2 harmonic
current limits
Rugged coldplate construction
Product Overview
The International Front End (IFE) is an
enclosed chassis mount, AC Front End
which may be used with VIPAC Arrays,
MegaModules or any of Vicor's 300V
input DC-DC converters to create a
complete, low profile, high density,
AC-DC power supply.
The IFE operates from worldwide AC
mains and includes autoranging line
rectification, integral EMI filtering,
hold-up capacitors, harmonic current
attenuation and transient suppression. The
IFE incorporates Vicor's passive harmonic
current attenuation technology and FARM
modules to deliver 500 Watts while
meeting EN61000-3-2 limits. All internal
heat producing components are coupled to
the chassis for optimal thermal transfer.
Two rugged, coldplate packages are
available -- one with threaded inserts and
the other with thru hole flanges -- which
may be mounted directly to a cabinet wall
or an existing heat sink for high
temperature operation.
The International Front Ends (IFE)
provide an off-the-shelf solution for many
custom and standard power supply
requirements where space constraints and
time to market are critical.
IFE
5
C
0
2
Product
Type
5 = 500 W
Termination
0 = Connector
Product Grade
C = -20C to 95C (BP)
T = -40C to 95C (BP)
Base Style
1 = External flange
2 = Internal threaded
Options
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
International Front End
Rev. 1.1
Page 2 of 7
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
Parameter
Min
Typ
Max
Unit
Notes
Output voltage
250
375
Vdc
Output power
500
550
Watts
90-132 / 180-264 Vac input
Hold-up time
90 Vac Input
23
ms
500 W output
115 Vac Input
58
ms
500 W output
90 Vac Input
93
ms
500 W output with 2460 F external
hold-up capacitor
115 Vac Input
229
ms
500 W output with 2460 F external
hold-up capacitor
Power fail warning time
6.5
ms
115 Vac input, 500 W output
Power fail warning time
25
ms
115 Vac input, 500 W output with 2460 F
external hold-up capacitor
Parameter
Min
Typ
Max
Unit
Notes
Operating input voltage
90
115
132
Vac
Autoranging (doubler mode)
Operating input voltage
180
230
264
Vac
Autoranging (bridge mode)
AC line frequency
47
63
Hz
Power factor
0.68
0.72
230 Vac input
Efficiency
94
96
%
Full load
Input current
115 Vac input
9
9.5
Arms
500 W output
230 Vac input
4.5
4.75
Arms
500 W output
Inrush current
115 Vac input
15
A pk
230 Vac input
30
A pk
INPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified.
Parameter
Min
Typ
Max
Unit
Notes
Safety approvals (pending)
cTVus, CE Marked
CE marked according to the Low Voltage Directive
72/23/EEC amendment 93/68/EEC
Isolation voltage (in to out)
none
Isolation voltage (I/O to chassis)
2121
Vdc
Leakage current
TBD
264 Vac input, 50Hz
SAFETY SPECIFICATIONS
Set your site on VICOR at www.vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
International Front End
Rev. 1.1
Page 3 of 7
PRELIMINARY
Parameter
Min
Typ
Max
Unit
Notes
Harmonic currents
EN61000-3-2
See Fig. 1
Voltage fluctuations and flicker
EN61000-3-3
Test in process
Electrical fast transient/burst
EN61000-4-4
Test in process
Input surge withstand
EN61000-4-5
Test in process
RF line conducted immunity
EN61000-4-6
Test in process
Voltage dips and interrupts
EN61000-4-11
Test in process
Conducted emissions
EN55022, Level B
See Fig. 2
ELECTROMAGNETIC COMPATIBILITY
Parameter
Min
Typ
Max
Unit
Notes
Enable
Low state current
50
mA
Bus normal
Low state resistance
15
ohms
To negative output
High state voltage
15
Vdc
150k internal pull up to 16 Vdc
Enable threshold
235
240
Vdc
Output bus voltage
Disable threshold
185
Vdc
Output bus voltage
Bus OK
Low state current
50
mA
Bus normal
Low state resistance
15
ohms
To negative output
High state voltage
15
Vdc
150k internal pull up to 16 Vdc
B OK true threshold
235
240
245
Vdc
Output bus voltage
B OK false threshold
200
205
210
Vdc
Output bus voltage
CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
MTBF
Coldplate and Cover material
aluminum
Weight
1.13 (2.5)
kg (lbs.)
Package size
L x W x H
Internal threaded (IFE5xx2)
240 x 100 x 26.25 (9.45" x 3.93" x 1.12")mm (in)
Thru hole flange (IFE5xx1)
260 x 100 x 26.25 (10.24" x 3.93" x 1.12")mm (in)
Mounting
Internal Threaded
M4 x 0.7
6 locations max. 12mm max penetration,
torque 15 in. lbs. (1.7Nm)
Flange clearance hole
M4 or #8
4 locations
Storage Temperature
C, T-Grade
-40
125
C
Operating Temperature
C-Grade
-20
95
C
T-Grade
-40
95
C
GENERAL SPECIFICATIONS
ELECTRICAL CHARACTERISTICS, continued
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
International Front End
Rev. 1.1
Page 4 of 7
Set your site on VICOR at www.vicorpower.com
PRELIMINARY
PERFORMANCE CHARACTERISTICS
Figure 2--Conducted line noise, EN55022-B
0.01
0.10
1.00
10.00
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Harmonic Number
Current (A)
Measured Values
Odd Harmonic Limits
Even Harmonic Limits
*
Figure 1 -- Measured harmonic current at 230 Vac, 50 Hz, 550 W vs. EN spec limits
*Measured values of even harmonics are below 0.01 A
Set your site on VICOR at www.vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
International Front End
Rev. 1.1
Page 5 of 7
PRELIMINARY
Connection Diagram
+In
PC (Gate In)
PR (Gate Out)
In
+In
PC (Gate In)
PR (Gate Out)
In
Vicor 300Vin
DC-DC
Converter
Vicor 300Vin
DC-DC
Converter
1 ST
2 SR
3 V
OUT
4 V
OUT
5 B
OK
6 EN
7 +V
OUT
8 +V
OUT
Pin#
Function
IFE
Output Connector
4 8
3 7
2 6
1 5
IFE
LI
L2/N
PE
Optional External
Hold-Up Capacitor
Mating Connector
Function
Description
Vicor P/N
Mfg. P/N
IFE Input fuse
5 x 20 mm, 10A fast acting
Wickman Series 194
IFE Input Connector
0.25'' male Faston
0.25'' insulated receptacle
IFE Output Connector
8 position AMP Duac
Housing
25056
AMP P/N 794657-8
Pins
24796
AMP P/N1-106529-2
Kit (Pins & Housing)
25073
VIPAC Array Input Connector J1
20 position AMP Duac
Housing
24795
AMP P/N 2-794657-0
Pins
24796
AMP P/N 1-106529-0
Kit (Pins & Housing)
24828
VIPAC Array Input Connector J2
Housing
27866
Molex 39-01-2025
Pins
27867
Molex 39-00-0039
Kit (Pins & Housing)
27881
1 ST
2 SR
3 V
OUT
4 V
OUT
5 B
OK
6 EN
7 +V
OUT
8 +V
OUT
Pin#
Function
IFE
LI
L2/N
PE
4 8
3 7
2 6
1 5
IFE
Output Connector
1-4 V
IN
5-7 +V
IN
8 NC/PR
Bus
9 PE
10
18 NC/PR
Bus
19 PE
20
Pin#
Function
J1 Input Connector
10 20
9 19
8 18
7 17
6 16
5 15
4 14
3 13
2 12
1 11
VIPAC Array
Optional External
Hold-Up Capacitor
+5V
1
2
J2
11-13 V
IN
14-17 +V
IN
Remote
Enable
+ Remote
Enable
J1
Pin#
Function
1
2
Enable
SR
J2 Input Connector
Figure 3--Connection diagram using IFE with Vicor 300 V
in
DC-DC converter(s)
Figure 4--Connection diagram using IFE with ViPAC Array